Skip to content

UGREEN 80180 Single-Port Keystone Wall Plate, 86×86mm, White

by UGREEN
Save 46% Save 46%
Original price Rs. 332.00
Original price Rs. 332.00 - Original price Rs. 332.00
Original price Rs. 332.00
Current price Rs. 179.00
Rs. 179.00 - Rs. 179.00
Current price Rs. 179.00
Request a quote

Overview

UGREEN 80180 is a single-position modular faceplate for finishing one low-voltage cable run at an indoor wall location. It holds one compatible keystone-form module and gives the outlet a clean, labelled finish. The installed module—not the faceplate—provides the actual connector and signal path. Below: selection, installation, compatibility, real limitations and safe use without treating a passive accessory as active networking equipment.

  • SKU 80180
  • ACTIVE product
UGREEN 80180 Single-Port Keystone Wall Plate, 86×86mm, White
86 × 86mmFaceplate size
14.7 × 19.5mmListed front opening
ABS + PCHousing
WhiteColour
Features

What it does well.

Key features

Role. It holds one compatible keystone-form module and gives the outlet a clean, labelled finish. The installed module—not the faceplate—provides the actual connector and signal path.

Compatibility boundary. One physically compatible keystone module and a suitable 86 × 86mm wall-box installation. The page specifically lists RJ45 LAN and RJ11 telephone use; any other keystone coupler must be checked for opening size, latch geometry, body depth and complete signal-path capability.

Performance reality. The plate cannot raise Ethernet category, video resolution or audio capability. Results are controlled by the module, fixed cable, patch leads and endpoints.

Important exclusion. This is not a network jack by itself, splitter, switch, router, converter, signal booster, mains outlet, outdoor cover or surface-mount box.

Where it fits in the connection

The system rule: every stage must match. The lowest-rated, damaged or incorrectly terminated component can limit speed, reliability, shielding, PoE operation or serviceability.

Use scenarios

Scenario 1. One labelled Ethernet outlet beside a desk, access point or television.

Scenario 2. One telephone outlet at reception or a workstation.

Scenario 3. A tidy serviceable pass-through using a separately keystone coupler.

Scenario 4. A room where the compatible module may later be replaced without changing the plate.

Compatibility and selection guide

Use when. One physically compatible keystone module and a suitable 86 × 86mm wall-box installation. The page specifically lists RJ45 LAN and RJ11 telephone use; any other keystone coupler must be checked for opening size, latch geometry, body depth and complete signal-path capability.

Do not assume. not a network jack by itself, splitter, switch, router, converter, signal booster, mains outlet, outdoor cover or surface-mount box. Before bulk purchase: trial the cable, module, plug or rack fit and complete one tested installation. Small physical differences can matter even within the same category name.

Selection checkpoint. Confirm port count, opening size, cable geometry, mounting depth and package contents. The connector family name alone is not a fit guarantee.

Setup and usability guidance

Work cleanly: dust, copper scraps and loose braid strands can create faults. Collect offcuts and inspect the finished area before energising connected equipment.

  1. Step 1: Measure the wall box, check the 86 × 86mm front size, screw positions and available depth.
  2. Step 2: Select one compatible module for the required low-voltage service; the listed front opening is 14.7 × 19.5mm.
  3. Step 3: Prepare and terminate the cable exactly as the module and cable manufacturer instruct.
  4. Step 4: Test the full link before closing the wall position.
  5. Step 5: Snap the module into the plate without forcing its latch, then fasten the faceplate evenly.
  6. Step 6: Label the port, close the shutter when unused and retest after final assembly.

Compatible devices and systems

Network endpoints. Routers, switches, access points, computers, printers, smart televisions, cameras and other RJ45 network equipment only through a correctly built compatible link.

Structured cabling. Wall outlets, patch panels, permanent cable and patch leads must share a suitable category, shielding design and wiring scheme.

PoE equipment. Possible only within the boundary: The plate has no conductive network path. PoE is possible only when every installed network component is correctly rated and terminated for the intended PoE system.

Operating systems. No operating-system driver is required for this passive accessory or manual tool; active adapters and switches are separate products.

What this product does

  • Provides its documented function: It holds one compatible keystone-form module and gives the outlet a clean, labelled finish. The installed module—not the faceplate—provides the actual connector and signal path.
  • Supports the stated compatibility class: One physically compatible keystone module and a suitable 86 × 86mm wall-box installation. The page specifically lists RJ45 LAN and RJ11 telephone use; any other keystone coupler must be checked for opening size, latch geometry, body depth and complete signal-path capability.
  • Can form part of a serviceable labelled network: when installed with matched components and tested.
  • Keeps infrastructure modular: damaged or changed portions can be traced and replaced without rebuilding unrelated equipment.
  • Uses no software: this product is passive or manual and has no configuration app.

What this product does not do

  • It is not a network jack by itself, splitter, switch, router, converter, signal booster, mains outlet, outdoor cover or surface-mount box.
  • It does not upgrade a lower-category cable or repair split pairs, poor conductor material, corrosion or bad device ports.
  • It does not guarantee PoE, bandwidth or error-free operation without a compliant complete link.
  • It does not remove the need for correct tools, installation practice, labelling and testing.
  • It should not be installed outdoors, in wet areas or beside mains wiring without a suitable compliant enclosure and qualified design.

What to do

Match. Match this SKU: use the title, construction and limits for 80180 rather than borrowing specifications from a similar family member.

Check. Check the complete path: confirm cable category, shielding, conductor construction, connector geometry, patch leads and endpoints.

Label. Label both ends: record room/port, wiring scheme and destination so later maintenance does not become guesswork.

Test. Test in stages: verify the cable or module before closing a wall plate or rack, then test again after final assembly.

Protect. Protect bend radius and strain relief: route cable gently and keep load away from contacts, IDC slots and device sockets.

What not to do

Do not force. Do not force parts: a keystone, plug, cable or tool that does not fit cleanly is probably the wrong geometry.

Do not miswire. Do not mix T568A and T568B accidentally: document the chosen scheme and check all eight conductors.

Do not over-untwist. Do not untwist pairs excessively: preserving pair geometry near termination matters to high-frequency performance.

Do not guess. Do not claim speed from appearance: clear housings, gold colour or a category marking do not replace complete-link testing.

Do not reuse damage. Do not use damaged parts: discard cracked housings, bent contacts, dull blades, loose shutters or failed crimp terminations.

Warnings and limitations

model limit: The plate cannot raise Ethernet category, video resolution or audio capability. Results are controlled by the module, fixed cable, patch leads and endpoints.

  • Electrical work nearby: isolate nearby mains circuits before opening a wall box and use a qualified installer wherever rules require one.
  • Indoor low-voltage scope: no outdoor ingress rating is established. Keep the product dry, clean and away from corrosive environments or excessive heat.
  • Category is system-wide: a Cat5e, Cat6 or Cat7 label on one part does not upgrade the remaining cable, patch leads, terminations or equipment.
  • Test before service: visual inspection is not enough. Verify conductor map and real link negotiation; professional installations may require certification testing.
  • Do not work on live mains: networking hardware is low voltage, but wall boxes and racks may be close to hazardous electrical circuits.

Troubleshooting checklist

No link. Confirm both active devices, patch leads and port selections. Then check conductor map, full insertion and the connector/cable fit.

Lower speed than expected. Verify negotiation settings and every component category. Excessive untwist, split pairs and unsuitable cable construction can pass continuity yet fail performance.

Intermittent link. Look for incomplete seating, weak strain relief, damaged latch, nicked conductor, IDC not fully closed or a crimp made with the wrong die.

PoE device restarts. Stop use and inspect conductor material, gauge, contact engagement, heat and the powered equipment budget. Do not continue with a hot or damaged termination.

Shield or noise concern. For shielded products, check end-to-end shield design and grounding practice. Mixing shielded and unshielded parts can defeat the intended system.

Port or label mismatch. Trace one cable at a time, compare labels at both ends and update records immediately after correction.

model check before ordering

Match SKU 80180, product type, port or die count, cable category/construction and package contents. Similar UGREEN networking accessories can look nearly identical while using different shielding, conductor fit, rack format or termination method.

Specifications

At a glance.

Brand / SKU
UGREEN 80180
Product role
a single-position modular faceplate for finishing one low-voltage cable run at an indoor wall location
Product type
Single-port modular wall faceplate
Module positions
1 standard-keystone position
Faceplate size
86 × 86mm
Listed front opening
14.7 × 19.5mm
Housing
ABS + PC
Colour
White
Listed weight
50g
Features
Dust shutter, one-click disassembly and label management
Electronics
None; passive
Source
https://www.ugreenindia.com/products/ugreen-single-port-wall-plate-white-80180

1 × UGREEN 80180 single-port wall faceplate and mounting screws as stated on the India listing. Keystone module, in-wall cable and patch lead are not identified as included.

Devices, cables, racks, wall boxes, modules, tools and testers are not included unless explicitly named above.

FAQs

Questions buyers ask.

What exactly is UGREEN 80180?
What is included in the package?
Which cables, modules or devices are compatible?
Does it guarantee the advertised network speed?
Can it be used in a PoE network?
Which tools are required?
Does it split, switch, route or convert a network connection?
How should a finished installation be tested?
Is it suitable for outdoor or mains-power installation?
What should I do if the link is intermittent?
How is this SKU different from similar UGREEN products?

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare