UGREEN 60558 Cat6 Unshielded RJ45 Modular Plugs, 100-Pack
Overview
UGREEN 60558 is a pack of 100 unshielded Cat6 8P8C modular plugs for terminating compatible Ethernet cable. Each clear plug accepts eight prepared conductors and is crimped to form a male cable end. The plug does not create network speed or correct a poor cable. Below: selection, installation, compatibility, real limitations and safe use without treating a passive accessory as active networking equipment.
- CAT6 UTP • 8P8C • 100 PACK
- SKU 60558
- ACTIVE product
- CAT6 UTP • 8P8C • 100 PACK

What it does well.

Key features
Role. Each clear plug accepts eight prepared conductors and is crimped to form a male cable end. The plug does not create network speed or correct a poor cable.
Compatibility boundary. Compatible unshielded Cat6 cable with the listed 0.8–1.1mm conductor diameter range. The page describes use with both single- and multi-strand conductor, so sample-fit and pull testing are important.
Performance reality. Listed for Gigabit Ethernet applications when the finished cable and complete channel comply. A plug by itself cannot certify 1000Mbps or 250MHz operation.
Important exclusion. This is not shielded, not automatically suitable for every Cat6/6A cable, not a pass-through design, not reusable after crimping and not a female extender.
Where it fits in the connection
The system rule: every stage must match. The lowest-rated, damaged or incorrectly terminated component can limit speed, reliability, shielding, PoE operation or serviceability.

Use scenarios
Scenario 1. Making compatible Cat6 UTP patch leads in required lengths.
Scenario 2. Repairing a cable end after verifying all eight conductors remain sound.
Scenario 3. Bulk home, office or rack installation work with sample-first checks.
Scenario 4. Maintaining spares for tested unshielded Cat6 cable construction.
Compatibility and selection guide
Use when. Compatible unshielded Cat6 cable with the listed 0.8–1.1mm conductor diameter range. The page describes use with both single- and multi-strand conductor, so sample-fit and pull testing are important.
Do not assume. not shielded, not automatically suitable for every Cat6/6A cable, not a pass-through design, not reusable after crimping and not a female extender. Before bulk purchase: trial the cable, module, plug or rack fit and complete one tested installation. Small physical differences can matter even within the same category name.
Setup and usability guidance
Work cleanly: dust, copper scraps and loose braid strands can create faults. Collect offcuts and inspect the finished area before energising connected equipment.
- Step 1: Confirm UTP Cat6 cable construction and the listed 0.8–1.1mm conductor fit.
- Step 2: Select T568A or T568B and keep the scheme consistent with the installation design.
- Step 3: Strip the minimum jacket length and avoid nicking insulation or excessive pair untwist.
- Step 4: Arrange, straighten and trim conductors evenly before full insertion.
- Step 5: Inspect colour order, conductor reach and jacket capture through the clear housing.
- Step 6: Crimp with the correct die, inspect every contact and test the wire map plus actual link speed.

Compatible devices and systems
Network endpoints. Routers, switches, access points, computers, printers, smart televisions, cameras and other RJ45 network equipment only through a correctly built compatible link.
Structured cabling. Wall outlets, patch panels, permanent cable and patch leads must share a suitable category, shielding design and wiring scheme.
PoE equipment. Possible only within the boundary: No separate PoE class is provided. PoE use requires suitable copper conductors, gauge, connector fit, termination quality, bundle temperature control and compliant powered equipment.
Operating systems. No operating-system driver is required for this passive accessory or manual tool; active adapters and switches are separate products.
What this product does
- Provides its documented function: Each clear plug accepts eight prepared conductors and is crimped to form a male cable end. The plug does not create network speed or correct a poor cable.
- Supports the stated compatibility class: Compatible unshielded Cat6 cable with the listed 0.8–1.1mm conductor diameter range. The page describes use with both single- and multi-strand conductor, so sample-fit and pull testing are important.
- Can form part of a serviceable labelled network: when installed with matched components and tested.
- Keeps infrastructure modular: damaged or changed portions can be traced and replaced without rebuilding unrelated equipment.
- Uses no software: this product is passive or manual and has no configuration app.

What this product does not do
- It is not shielded, not automatically suitable for every Cat6/6A cable, not a pass-through design, not reusable after crimping and not a female extender.
- It does not upgrade a lower-category cable or repair split pairs, poor conductor material, corrosion or bad device ports.
- It does not guarantee PoE, bandwidth or error-free operation without a compliant complete link.
- It does not remove the need for correct tools, installation practice, labelling and testing.
- It should not be installed outdoors, in wet areas or beside mains wiring without a suitable compliant enclosure and qualified design.
What to do
Match. Match this SKU: use the title, construction and limits for 60558 rather than borrowing specifications from a similar family member.
Check. Check the complete path: confirm cable category, shielding, conductor construction, connector geometry, patch leads and endpoints.
Label. Label both ends: record room/port, wiring scheme and destination so later maintenance does not become guesswork.
Test. Test in stages: verify the cable or module before closing a wall plate or rack, then test again after final assembly.
Protect. Protect bend radius and strain relief: route cable gently and keep load away from contacts, IDC slots and device sockets.

What not to do
Do not force. Do not force parts: a keystone, plug, cable or tool that does not fit cleanly is probably the wrong geometry.
Do not miswire. Do not mix T568A and T568B accidentally: document the chosen scheme and check all eight conductors.
Do not over-untwist. Do not untwist pairs excessively: preserving pair geometry near termination matters to high-frequency performance.
Do not guess. Do not claim speed from appearance: clear housings, gold colour or a category marking do not replace complete-link testing.
Do not reuse damage. Do not use damaged parts: discard cracked housings, bent contacts, dull blades, loose shutters or failed crimp terminations.
Warnings and limitations
model limit: Listed for Gigabit Ethernet applications when the finished cable and complete channel comply. A plug by itself cannot certify 1000Mbps or 250MHz operation.
- Sharp tools and contacts: keep fingers clear of blades, IDC contacts, trimmed conductors and crimp dies. Wear appropriate eye protection during cutting and termination.
- Indoor low-voltage scope: no outdoor ingress rating is established. Keep the product dry, clean and away from corrosive environments or excessive heat.
- Category is system-wide: a Cat5e, Cat6 or Cat7 label on one part does not upgrade the remaining cable, patch leads, terminations or equipment.
- Test before service: visual inspection is not enough. Verify conductor map and real link negotiation; professional installations may require certification testing.
- Do not work on live mains: networking hardware is low voltage, but wall boxes and racks may be close to hazardous electrical circuits.

Troubleshooting checklist
No link. Confirm both active devices, patch leads and port selections. Then check conductor map, full insertion and the connector/cable fit.
Lower speed than expected. Verify negotiation settings and every component category. Excessive untwist, split pairs and unsuitable cable construction can pass continuity yet fail performance.
Intermittent link. Look for incomplete seating, weak strain relief, damaged latch, nicked conductor, IDC not fully closed or a crimp made with the wrong die.
PoE device restarts. Stop use and inspect conductor material, gauge, contact engagement, heat and the powered equipment budget. Do not continue with a hot or damaged termination.
Shield or noise concern. For shielded products, check end-to-end shield design and grounding practice. Mixing shielded and unshielded parts can defeat the intended system.
Port or label mismatch. Trace one cable at a time, compare labels at both ends and update records immediately after correction.
model check before ordering
Match SKU 60558, product type, port or die count, cable category/construction and package contents. Similar UGREEN networking accessories can look nearly identical while using different shielding, conductor fit, rack format or termination method.
At a glance.
- Brand / SKU
- UGREEN 60558
- Product role
- a pack of 100 unshielded Cat6 8P8C modular plugs for terminating compatible Ethernet cable
- Product type
- Unshielded Cat6 modular plugs
- Cable category
- Cat6 U/UTP
- Connector
- 8P8C male modular plug
- Pack quantity
- 100
- Housing
- Clear plastic
- Contacts
- 3U gold-plated, as listed
- Listed conductor diameter
- 0.8–1.1mm
- Listed application
- Up to 1000Mbps with a compliant finished link
- Termination
- Crimp; compatible tool required
- Electronics
- None; passive
- Source
- https://www.ugreenindia.com/collections/networking-accessories/products/ugreen-cat-6-u-utp-unshielded-modular-plug-lan-high-speed-gigabit-network-compatible-with-router-modem-smart-tv-pc-laptop-100-pcs60558
100 × UGREEN 60558 Cat6 unshielded 8P8C modular plugs. Cable, boots, crimping tool and tester are not identified as included.
Devices, cables, racks, wall boxes, modules, tools and testers are not included unless explicitly named above.